SilverStone Strider Platinum 1000W & 1200W - Hot Test Results

Enhance is an OEM who does not get concerned with power quality when the figures are good enough and these two units are no exception. The voltage ripple figures are mediocre, with the 3.3V/5V voltage lines flirting with the 50 mV recommended design limit. 

SilverStone ST1000-PT Main Output
Load (Watts) 202.7 W 505.92 W 752.48 W 997.17 W
Load (Percent) 20.27% 50.59% 75.25% 99.72%
  Amperes Volts Amperes Volts Amperes Volts Amperes Volts
3.3 V 2.29 3.36 5.72 3.36 8.58 3.33 11.44 3.32
5 V 2.01 5.06 5.04 5.06 7.55 5 10.07 5
12 V 15.2 12.16 37.99 12.14 56.99 12.04 75.99 11.96
Line Regulation
(20% to 100% load)
Voltage Ripple (mV)
20% Load 50% Load 75% Load 100% Load CL1
12V
CL2
3.3V + 5V
3.3V 1.2% 16 30 36 48 20 42
5V 1.2% 20 24 30 44 20 40
12V 1.6% 18 26 40 56 54 36

The 12V lines hold better, with the ST1000-PT and the ST1200-PT reaching up to 56 mV and 50 mV at maximum load respectively, which is half of the 120 mV recommended design limit but still considerably higher than what the competition nowadays offers. Voltage regulation is good and similar for both units, at about 1% for the 3.3V/5V lines and 1.6% for the 12V line across the nominal load range.

SilverStone ST1200-PT - Main Output
Load (Watts) 243.59 W 608.13 W 902.73 W 1197.78 W
Load (Percent) 20.3% 50.68% 75.23% 99.82%
  Amperes Volts Amperes Volts Amperes Volts Amperes Volts
3.3 V 2.31 3.35 5.79 3.34 8.68 3.33 11.57 3.32
5 V 2.04 5.1 5.09 5.09 7.64 5.05 10.18 5.04
12 V 18.51 12.18 46.29 12.16 69.43 12.03 92.57 11.97
Line Regulation
(20% to 100% load)
Voltage Ripple (mV)
20% Load 50% Load 75% Load 100% Load CL1
12V
CL2
3.3V + 5V
3.3V 1.1% 16 28 36 44 20 38
5V 1.15% 18 20 30 42 20 44
12V 1.7% 16 22 34 50 50 38

 

High ambient temperatures have a small but measurable effect on the energy conversion efficiency of the Strider Platinum units. The average conversion efficiency of the two units drops by about 0.6%, to 91.4% and 91.6% for the ST1000-PT and the ST1200-PT respectively, which is very good considering the very large difference in ambient temperature. This hints that the components that the manufacturer is using are capable of maintaining high performance at higher temperatures and/or significantly oversized for their tasks.

Regardless of the high ambient temperature, both units disabled their fans when the load was very low but would immediately speed up their fans when the load increased above just 100 Watts. The two units were not really louder compared to our room temperature tests, meaning that they were already running their fans at maximum speed before, even though the internal temperatures were much lower than the >80°C figures we get inside our hotbox.