Gaming Performance: 4K

Last, we have our 4K gaming results.

Civilization VI

(a-5) Civilization VI - 4K Min - Average FPS(a-6) Civilization VI - 4K Min - 95th Percentile

World of Tanks

(b-7) World of Tanks - 4K Max - Average FPS(b-8) World of Tanks - 4K Max - 95th Percentile

Borderlands 3

(c-5) Borderlands 3 - 4K VLow - Average FPS(c-6) Borderlands 3 - 4K VLow - 95th Percentile

Grand Theft Auto V

(e-5) Grand Theft Auto V - 4K Low - Average FPS(e-6) Grand Theft Auto V - 4K Low - 95th Percentile

Red Dead Redemption 2

(f-5) Red Dead 2 - 4K Min - Average FPS(f-6) Red Dead 2 - 4K Min - 95th Percentile

F1 2022

(g-7) F1 2022 - 4K High - Average FPS(g-8) F1 2022 - 4K High - 95th Percentile

Hitman 3

(h-7) Hitman 3 - 4K High - Average FPS(h-8) Hitman 3 - 4K High - 95th Percentile

Total War: Warhammer 3

(i-4) Total War Warhammer 3 - 4K High - Average FPS

We noticed some discrepancies in our Cyberpunk 2077 testing at 1440p and 4K; we will publish these results once we identify the issue.

As we've seen throughout our game testing, things are quite competitive between the top contenders, including the Intel Core i9-13900K, the Core i9-12900K/KS, and the AMD Ryzen 9 7950X chips. In our 4K testing, however, where the Ryzen 7 5800X3D and loads of 3D V-Cache can't be utilized, then the Core i9-13900K and Core i5-13600K perform very well. 

Gaming Performance: 1440p Closing Thoughts
POST A COMMENT

169 Comments

View All Comments

  • OreoCookie - Tuesday, October 25, 2022 - link

    Yes, TDP has a meaning, and technically, neither company is using it correctly. Back in the good-ol’ days when TDP was really max power under load, it easily allowed you to spec a cooler. Clock boosts were meant to be temporary, transient states so that *on average*, you’d still lie within the thermal budget of the cooler. Obviously, we are well past that.

    So yes, AMD is playing it a bit loose (+31 %). But Intel is playing it ridiculous: the i9’s max power (as tested here) is 2.7x (!) their “TDP”.
    Reply
  • shaolin95 - Thursday, October 20, 2022 - link

    AMD does the same thing. dont be a fanboy Reply
  • yh125d - Thursday, October 20, 2022 - link

    If you're equating AMD going ~50w over TDP to intel going 210w over TDP, you're being the fanboy. Reply
  • Yojimbo - Friday, October 21, 2022 - link

    AMD's turbo clocking is more than 50W. Reply
  • Yojimbo - Friday, October 21, 2022 - link

    i checked and it's 60 W. That doesn't make AMD "less dishonest”. Neither company are being dishonest. It means AMD does not intend their desktop products to be used in lower power products. If you want to design a product around a Ryzen 7950X you need a 170 W cooling solution. Whereas you can put an i9 13900K in a product that can only dissipate 125 W. That's the difference between the two processors in terms if the TDPs. That's what TDP means. Reply
  • Truebilly - Friday, October 21, 2022 - link

    I'd like to see someone run that 13900k with 120mm rad Reply
  • Wrs - Friday, October 21, 2022 - link

    I mean, it works. The processor automatically steps down the v/f curve and doesn't hiccup with a puny cooler good for 140'ish W. I tested a 12900k with a low-profile AXP-200 from my Skylake days. Performance wasn't bad, over 4GHz all 16 cores. I left all the OC settings on, or else stock E-cores would be 3.9GHz. Reply
  • nandnandnand - Thursday, October 20, 2022 - link

    Go look at some efficiency curves for the 7950X and 13900K, for example at 19:00 in Hardware Unboxed's review: https://www.youtube.com/watch?v=P40gp_DJk5E Reply
  • Yojimbo - Friday, October 21, 2022 - link

    none of the companies "do” anything here. The "doing" is by the people who, though they are ignorant, write seething rants in comment sections damning the companies. Reply
  • bji - Friday, October 21, 2022 - link

    This issue would be a lot less contentious if technical sites like Anandtech actually used their expertise to curate information presented. They just shouldn't even show TDP as it's simply not relevant to the end users who are reading the articles. They should have some standard benchmark they run to determine peak and maximum sustained power draws and show ONLY those values in any charts. Reply

Log in

Don't have an account? Sign up now