Testing Methodology

Although the testing of a cooler appears to be a simple task, that could not be much further from the truth. Proper thermal testing cannot be performed with a cooler mounted on a single chip, for multiple reasons. Some of these reasons include the instability of the thermal load and the inability to fully control and or monitor it, as well as the inaccuracy of the chip-integrated sensors. It is also impossible to compare results taken on different chips, let alone entirely different systems, which is a great problem when testing computer coolers, as the hardware changes every several months. Finally, testing a cooler on a typical system prevents the tester from assessing the most vital characteristic of a cooler, its absolute thermal resistance.

The absolute thermal resistance defines the absolute performance of a heatsink by indicating the temperature rise per unit of power, in our case in degrees Celsius per Watt (°C/W). In layman's terms, if the thermal resistance of a heatsink is known, the user can assess the highest possible temperature rise of a chip over ambient by simply multiplying the maximum thermal design power (TDP) rating of the chip with it. Extracting the absolute thermal resistance of a cooler however is no simple task, as the load has to be perfectly even, steady and variable, as the thermal resistance also varies depending on the magnitude of the thermal load. Therefore, even if it would be possible to assess the thermal resistance of a cooler while it is mounted on a working chip, it would not suffice, as a large change of the thermal load can yield much different results.

Appropriate thermal testing requires the creation of a proper testing station and the use of laboratory-grade equipment. Therefore, we created a thermal testing platform with a fully controllable thermal energy source that may be used to test any kind of cooler, regardless of its design and or compatibility. The thermal cartridge inside the core of our testing station can have its power adjusted between 60 W and 340 W, in 2 W increments (and it never throttles). Furthermore, monitoring and logging of the testing process via software minimizes the possibility of human errors during testing. A multifunction data acquisition module (DAQ) is responsible for the automatic or the manual control of the testing equipment, the acquisition of the ambient and the in-core temperatures via PT100 sensors, the logging of the test results and the mathematical extraction of performance figures.

Finally, as noise measurements are a bit tricky, their measurement is being performed only manually. Fans can have significant variations in speed from their rated values, thus their actual speed during the thermal testing is being acquired via a laser tachometer. The fans (and pumps, when applicable) are being powered via an adjustable, fanless desktop DC power supply and noise measurements are being taken 1 meter away from the cooler, in a straight line ahead from its fan engine. At this point we should also note that the Decibel scale is logarithmic, which means that roughly every 3 dB(A) the sound pressure doubles. Therefore, the difference of sound pressure between 30 dB(A) and 60 dB(A) is not "twice as much" but nearly a thousand times greater. The table below should help you cross-reference our test results with real-life situations.

The noise floor of our recording equipment is 30.2-30.4 dB(A), which represents a medium-sized room without any active noise sources. All of our acoustic testing takes place during night hours, minimizing the possibility of external disruptions.

<35dB(A) Virtually inaudible
35-38dB(A) Very quiet (whisper-slight humming)
38-40dB(A) Quiet (relatively comfortable - humming)
40-44dB(A) Normal (humming noise, above comfortable for a large % of users)
44-47dB(A)* Loud* (strong aerodynamic noise)
47-50dB(A) Very loud (strong whining noise)
50-54dB(A) Extremely loud (painfully distracting for the vast majority of users)
>54dB(A) Intolerable for home/office use, special applications only.

*noise levels above this are not suggested for daily use

The AMD Coolers Testing Results, Maximum Fan Speed (12 Volts)
Comments Locked

82 Comments

View All Comments

  • ZeDestructor - Monday, July 25, 2016 - link

    Yes they could, but then you'd be reducing yields, which would drive final price up.
  • pseudoid - Friday, July 22, 2016 - link

    Did I miss the part about the SkyLake (LGA 1151) uPs? The Intel boxed Core I7-6700K Skylake uP comes with no cooling fan. I found that the Noctua coolers are a better fit for my needs, especially the iron-clad 3yr. warranty!
  • LordanSS - Friday, July 22, 2016 - link

    Thank you for this review.

    Although I already expected the 212 EVO to pull ahead (it's tough to match it on price/performance), was interesting to see the differences on the other stock ones. And the Wraith came out as a pleasant surprise.

    Maybe in the US it's all about Intel and their CPUs, but in other areas of the world, like here in South America, AMD and their APUs are not doing poorly, with very good (local) pricing and decent enough performance for usual Office and light work cases, and people even use them for League of Legends and DotA2, which are very popular games around here, and not too graphics intensive.
  • zodiacfml - Friday, July 22, 2016 - link

    I went to Intel's list of Skylake desktop CPU's and found only two that has around 90W of TDP.
    The 212 is only 25C above ambient at 150W.
    Anything larger or more expensive than the 212 is pretty much overkill for modern CPUs.
  • wintermute000 - Friday, July 22, 2016 - link

    "modern [Intel standard desktop] CPUs"

    FIFY
  • Ascaris - Sunday, July 24, 2016 - link

    "modern [Intel standard desktop] CPUs at their stock clock and voltage settings"
  • Byte - Saturday, July 23, 2016 - link

    The hyper 212 is a bit overrated and dated, but then again i used it to test a bunch of 6700k i had fun delidding with liquid ultra and it kept them cool to 4.6/4.7GHz pretty easy.
  • phylop - Saturday, July 23, 2016 - link

    I would love to see you guys post an anthology of coolers throughout the ages. Include comparing how older coolers would perform on modern CPUs and vice versa.
  • Teknobug - Saturday, July 23, 2016 - link

    The 212 is probably the best bang per buck for HSF, can't go wrong with it. I also have a TX3 which is nearly as effective as the 212 and about $10 less, however there is one thing you must do if you're going to use it on an Intel system- ditch the flimsy black/white plastic locks and steal the ones from an Intel HSF to replace them with. Once you do that, you got a pretty solid HSF even for decently OC'd CPU's.
  • Zap - Saturday, July 23, 2016 - link

    IMO stock coolers are perfectly fine for systems that run stock speeds and aren't intended to sit running torture tests all day.

    Noisy? Did you enable "smart fan" in BIOS? Is that in normal use or hammering it with Prime95?

    Bad temperatures? Did you install it properly? For whatever reason many people can't figure out push pins when they are super simple to use. Is your temperature "comfort level" calibrated for overclocks when you're just building a stock clocked system for family to use? Fact: Your stock clocked CPU does not require low temperatures.