Concluding Remarks

Ten different 4 TB hard drives have been analyzed for NAS and DAS applications. Coming to the business end of the review, it is clear that there is no 'one size fits all' model in this area. The hard drives themselves were launched targeting different markets and their resulting performance varies accordingly. However, based on our test results we can arrive at the following conclusions:

The lowest power consumption numbers were recorded, as expected, with the 5400/5900 RPM drives: the WD Reds, Seagate NAS HDDs and the Seagate Terascale units. While the WD Red drew the least power in the resync test, the Terascale and the NAS HDD drew less power during our access sequence tests (though not by much). If power constraints are a primary factor any one of the three would be a good choice. However with that said, despite possessing the highest workload rating of the three the Terascale has the lowest MTBF, coming in at a rating of 800K hours versus 1M hours for the Western Digital and Seagate NAS drives. Consequently depending on the usage scenario the extra premium for the Terascale might not be worth it.

The best overall performance is recorded by the Seagate Enterprise Capacity v4, thanks to its clear lead in the random access patterns segment of the multi-client evaluation. The drawback being that the part is quite difficult to come across for purchase and carries a premium wherever it becomes available.

Meanwhile the Toshiba drive is a strong value proposition as the cheapest enterprise hard drive in the scalable storage class of drives. Even though the MSRP and street price put it in the same category as that of the Seagate Terascale, we have seen occasional deals which give it only a slight premium over the non-enterprise WD Red and the Seagate NAS HDDs. Otherwise the Ultrastar 7K4000 SAS unit is also available for rock bottom prices from third-party sellers on Amazon, and is a good candidate for users running SAS-based storage servers. Though without a broader sample space it is difficult to recommend it further.

Finally we have the WD Red Pro, which aims to strike a balance between performance, power consumption and price. The attractive pricing (given the warranty) makes up for the fact that it doesn't impress in any particular category compared to the competition. If Seagate's Enterprise Capacity drive were to retail for the same price as that of the Red Pro, the choice would be a no-brainer in favour of the Seagate unit. But right now that is not the case, and Western Digital continues to present a unique value proposition with the Red Pro lineup.

All in all, there are plenty of options for NAS users looking to stock up their NAS units with high capacity drives. Though not at the bleeding edge of capacity, today's 4TB drives offer a good mix of pricing, performance, and capacity; and for the cautious buyer 4TB drives offer an alternative to the potential risk in going the new technology route with 6 TB drives. In the end, with the right data in hand it's easy enough to find the best fit by taking into consideration the expected workload and desired price points.

RAID-5 Benchmarking - Miscellaneous Aspects
Comments Locked

62 Comments

View All Comments

  • sin_tax - Thursday, August 21, 2014 - link

    Transcoding != streaming. Most all NAS boxes are underpowered when it comes to transcoding.
  • jaden24 - Friday, August 8, 2014 - link

    Correction.

    WD Red Pro: Non-Recoverable Read Errors / Bits Read 10^15
  • Per Hansson - Friday, August 8, 2014 - link

    I'm not qualified to say for certain, but I think it's just marketing
    bullshit to make the numbers look better when infact they are the same?

    Non-Recoverable Read Errors per Bits Read:
    <1 in 10^14 WD Red
    <10 in 10^15 WD Red Pro
    <10 in 10^15 WD Se

    Just for reference the Seagate Constellation ES.3, Hitachi Ultrastar He6 &
    7K4000 are all rated for: 1 in 10^15
  • shodanshok - Friday, August 8, 2014 - link

    Hi, watch at the specs carefully: WD claim <10 errors for 10^15 bytes read.
    Previously, it was <1 each 10^14.

    In other word, they increase the exponent (14 vs 15), but the value is (more or less) the same!
  • jaden24 - Friday, August 8, 2014 - link

    Nice catch. I just went and looked up all of them.

    RE = 10 in 10^16
    Red Pro = 10 in 10^15
    SE = 10 in 10^15
    Black = 1 in 10^14
    Red = 1 in 10^14
    Green = 1 in 10^14

    It looks like they switched to this marketing on RE and SE. The terms are in black and white, but it is a deviation from a measurement scheme, and can only be construed as deceiving in my book. I love WD, but this pisses me off.
  • isa - Friday, August 8, 2014 - link

    For my home/home office use, the most important aspect by far for me is reliability/failure rates, mainly because I don't want to invest in more than 2 drives or go beyond Raid 1. I realize the most robust reliability info is based on several years of statistics in the field, but is their any kind of accelerated life test that Anandtech can do or get access to that has been proven to be a fairly reliable indicator of reliability/failure rates differences across the models? I'm aware of the manufacturer specs, but I don't regard those as objective or measured apples-apples across manufacturers.

    If historical reliability data is fairly consistent across multiple drives across a manufacturers' line, perhaps at least provide that as a proxy for predicted actual reliability. Thanks for considering any of this!
  • NonSequitor - Friday, August 8, 2014 - link

    If you're really concerned about reliability, you need double-parity rather than RAID-1. In a double parity situation the system knows which drive is returning bad data. With RAID-1 is doesn't know which drive is right. Of course either way you should have a robust backup infrastructure in place if your data matters.
  • shodanshok - Friday, August 8, 2014 - link

    Mmm... it depends.

    If you speak about silent data corruption (ie: read error that aren't detected by the build in ECC), RAIDZ2 and _some_ RAID6 implementation should be able to isolate the wrond data. However this require that for every read both parity data (P and Q) are re-calculated, hammering the disk subsystem and the controller's CPU. RAIDZ2, by design, do this precise thing (N disks in a single RAIDZ array give you the same IOPS that a single disk), but many RAID6 implementation simply don't do that for performance reason (Linux MDRAID, for example, don't to it).

    If you are referring to UREs, even a single parity scheme as RAID5 is sufficient for non-degraded conditions. The true problem is for the degraded scenario: in this case and on most hardware RAID implementation, a single URE error will kill your entire array (note: MDRAID behave differently and let you to recover _even_ from this scenario, albeit with some corrupted data and in different manner based on its version). In this case, a double parity scheme is a big advantage.

    On the other hand, while mirroring is not 100% free from URE risk, it need to re-read the content of a _single_ disk, not the entire array. In other word, it is less exposed to URE problem then RAID5 simply because it has to read less data to recover from a failure (but with current capacities RAID6 is even less exposed to this kind of error).

    Regards.
  • NonSequitor - Friday, August 8, 2014 - link

    MDRAID will recheck all of the parity during a scrub. That's really enough to catch silent data corruption before your backups go stale. It's not perfect but is a good balance between safety and performance. The problem with RAID5 compared to RAID6 is that in a URE situation the RAID5 will still silently produce garbage as it has no way to know if the data is correct. RAID6 is at least capable of spotting those read errors.
  • shodanshok - Friday, August 8, 2014 - link

    I think you are confusing URE with silent dats corruption. An URE in non-degraded RAID 5 will not produce any data corruption, it will simply trigger a stripe reconstruction.

    An URE in degraded RAID 5 will not produce any data corruption, but it will result in a "dead" or faulty array.

    A regular scrub will prevents unexpected UREs, but if a drive suddenly become returning garbage, even regular scrubs can not do anything.

    In theory, RAID6 can identify what drive is returning garbage because it has two different parity data. However, as stated above, that kind of control is avoided due to the severe performance penalties it implies.

    RAIDZ2 take the safe path and do a complete control for every read, but as results its performance is quite low.

    Regards.

Log in