Voltage Regulation

+3.3V Regulation/Ripple and Noise
Load Voltage
5% +1.52% (2mV)
10% +1.52% (3mV)
20% +1.52% (12mV)
50% +0.91% (11mV)
80% +0.61% (21mV)
100% +0.30% (23mV)
110% +0.30% (25mV)
Crossload +12V max. +1.52%
Crossload +3.3V/+5V max. +1.21%

 

+5V Regulation/Ripple and Noise
Load Voltage
5% +3.40% (2mV)
10% +3.40% (5mV)
20% +3.20% (12mV)
50% +3.00% (17mV)
80% +2.40% (17mV)
100% +2.40% (20mV)
110% +2.40% (22mV)
Crossload +12V max. +0.20%.
Crossload +3.3V/+5V max. -0.20%

 

+12V Regulation (Worst Ouput)/Ripple and Noise (Worst Output)
Load Voltage
5% +1.42% (7mV)
10% +0.92% (15mV)
20% +0.75% (25mV)
50% +0.58% (38mV)
80% +0.58% (40mV)
100% +0.92% (47mV)
110% +0.75% (51mV)
Crossload +12V max. +0.42%
Crossload +3.3V/+5V max. +1.33%

Noise Levels

Loudness and Temperatures (Δϑ to 22.1 °C ambient temperature)
Load Opinion
5% choke chirping (1.7 °C)
10% choke chirping (2.6 °C)
20% choke chirping (4.6 °C)
50% choke chirping (8.3 °C)
80% choke chirping (15.9 °C)
100% choke chirping (18.6 °C)
110% choke chirping (20.8 °C)

Efficiency and PFC

Efficiency and Power Factor 115 VAC
Load Efficiency PFC
5% 71.19% 0.879
10% 85.40% 0.911
20% 89.53% 0.958
50% 91.82% 0.988
80% 91.09% 0.991
100% 90.74% 0.992
110% 89.47% 0.993

 

Efficiency and Power Factor 230 VAC
Load Efficiency PFC
5% 73.67% 0.864
10% 85.86% 0.883
20% 90.10% 0.939
50% 92.14% 0.984
80% 91.60% 0.988
100% 91.06% 0.990
110% 90.84% 0.990

Since there is no fan, there's not much point in measuring sound pressure levels, but what about noise from the electronics? There is an audible "chirping" from the PFC choke and both DC-to-DC converters. However, this could be an individual case. The difference between the ambient and the exhaust temperature is relatively high. We've tested the power supply with a room temperature of just 22.1 °C, which is usually no problem for a high-quality PSU.

The voltage quality is absolutely acceptable. Small transients are no big deal and the smaller rails are always below 25mV which is less than 0.5% ripple. +12V shows only 51mV,  but we should keep in mind that Seasonic had no more than 20mV on all outputs. Overall the voltage regulation is decent. There is hardly any drop on the +12 V and +3.3V rail but +5 V could be closer the optimal value.

Considering the 80 Plus Gold certification, we expected high efficiency and that's exactly what we got. The only blemish is that 5% load "only" comes in at 71-74%. At this point the efficiency could be better than 75%, but we don't want to overdo things.

Internal Design and Components Conclusion
Comments Locked

41 Comments

View All Comments

Log in