115VAC Efficiency, Power loss and PFC

Efficiency is one of the most important factors nowadays in power supplies. PSU marketing and advertising are completely dependent on efficiency in most cases. At 115VAC we have measured a little more than 80% efficiency from 25% to 60% load. That is surely an impressive number with 115VAC. It is nice to see that Silverstone is able to maintain this high efficiency through the full spectrum of loads and not only for a few specific loads like some other power supplies. After it reached its zenith it steadily declines in efficiency, but not too rapidly.


Due to a high efficiency the power loss was in quite good shape as well. The thinner this graph is the less power loss we have measured. The loss of power is always higher towards the highest load which results in the figure below.


Even when you turn your PC off it is, unfortunately, still using energy if you don't hit the hard power switch on the backside. This is the standby function which lets the PC start with soft power features like wake on LAN. Since the PC is on standby it is always using energy from the grid. We have included this test to check power supply's standby function and their energy usage while the PC is off. With 115VAC the OP650 is using 1.19 watts of energy while doing "nothing" which is not a very high result. If you leave the PC off for a long period of time, you should still always hit the switch or unplug the cable.

To test the standby-efficiency we are using the loads of 0.1, 0.5 and 3.0 Ampere on the 5VSB rail while the power supply is not running. The result is the efficiency of each load shown below. The results are quite average but not low. A standby-efficiency of 72% with 3 Ampere of load is very good.


Power factor correction works fine and delivers the usual high results. It always performs better at 115VAC as opposed to 230VAC.



115VAC 12V Rail Tests 230VAC 3.3V, 5V, and 5Vsb Tests
Comments Locked

46 Comments

View All Comments

  • YellowWing - Friday, July 13, 2007 - link

    In a prior article you showed us the box you use for testing power supplies. I don't remember reading how the heat generated by the power supplies is removed from the sealed box. Does the temp of the air in the box rise with time? Would the drop off in voltage be less with full ventilation?
  • YellowWing - Friday, July 13, 2007 - link

    Brownouts have caused power supply failures for me in the past. How about dialing the input voltage down to 90 or so and see what happens.

    From experience I can say that some supplies don't survive at lower input voltages.
  • DerekWilson - Friday, July 13, 2007 - link

    we are considering looking at 90V input. Thanks for the suggestion.
  • bpt8056 - Friday, July 13, 2007 - link

    I just want to say that I thought AT did a great job on the review. Keep up the great work!
  • puffpio - Friday, July 13, 2007 - link

    Great article..looking forward to many many more

    On one of the graphs of the 230V tests, it is labeled as 115V
  • jonnyGURU - Friday, July 13, 2007 - link

    Good job. Clearly a lot of effort was put behind putting the methodology and this review together.

    Couple questions..

    1. How much of the voltage drop shown would you contribute to the resistance created by the interface board and wires located between the end of the PSU's connector and the actual load. This isn't my favorite power supply, but I know the voltage regulation isn't nearly as bad as you have it graphed. And naturallly, since load also creates resistance, your voltage is going to decrease exponentially if you're not loading and measuring at the end of the connector. Since you're using a Chroma, I know you're not loading and measuring at the connector. Perhaps you could rig a DMM to measure voltages at the end of the connector instead of reporting what the Chroma is telling you since the Chroma is going to be incorrect since it doesn't take into consideration this added resistance.

    2. Do you think it's possible to define "10%, 20%, etc." as it pertains to your loads. Naturally, you can't load all rails by 80%, 90%, 100%" because you'd easily exceed the power supplies capabilities. And certainly you're not loading the +12V with 80%, 90% 100% and then filling up the remainder with a 3.3V and 5V load because then you would crossload the PSU with an unusually high +12V load.

    3. And, at risk of sounding like I'm beating a dead horse, ripple and noise results. We all know spec is 1%, and ripple and noise does typically increase with load. It would be nice to see if the power supplies being tested stay within that spec. through out it's total advertised capability.

    Thanks and I look forward to the next PSU review!
  • mcvan - Saturday, July 14, 2007 - link

    Like Johnny said. ;)

    Another issue pertinent to the extreme sag in voltage lines and perhaps to the soaring temperatures is to ask how long the PSU was run at each load level (and in total) and what was the air temperature at the PSU intake? Maybe the test box is just letting the PSU get way too unnaturally hot, and this has a deleterious effect on performance. This test box is not the same as thermal control chamber where you can dial in a specific target temperature, which will then be held constant by the chamber throughout the testing.

    Since the test box is well insulated and sealed, there is a direct correlation between time spent with the PSU on and internal air temperature. No matter how the PSU is cooled, at any load, the temperature of the test box should rise continuously (even if only incrementally at very low load) as long as the PSU is running. This is a significant uncontrolled and unreported factor. That PSU intake temperature will be dictated by a complex mix of factors, by too many variables --

    -starting ambient air temp in the box
    -how long the PSU is kept running in the box and at which loads
    -heat loss out of the box
    -efficiency curve of the PSU
    -fan and fan controller characteristics

    If the time spent at each load and the starting ambient temp is kept the same for each and all PSUs, then the variables are correctly contained to the PSUs being tested. Then differences in the air temperature at the intake at any given power level for each PSU would reflect real differences in the cooling system and efficiency of each PSU. It would ensure a more level thermal playing field.
  • qpwoei - Friday, July 13, 2007 - link

    quote:

    And, at risk of sounding like I'm beating a dead horse


    While we're beating dead horses, I'll land a few blows on the dynamic load response horse as well :)
  • SilthDraeth - Friday, July 13, 2007 - link

    Seems like you know what you are talking about. I hope they take some of your points into consideration, since they all seem very valid.
  • jonnyGURU - Friday, July 13, 2007 - link

    Thanks. But I'm just an old hack. ;)

Log in

Don't have an account? Sign up now