12V DC Output

12V DC Output
Percentage Amperage 12V1 Amperage 12V2 Amperage 12V3 Amperage 12V4 Wattage in total Wattage
(All rails combined)
10% 1.11 1.11 1.54 1.54 62.88 77.95
20% 2.21 2.21 3.07 3.07 125.04 158.11
30% 3.32 3.32 4.61 4.61 187.41 236.48
40% 4.42 4.42 6.14 6.14 248.94 314.35
50% 5.53 5.53 7.68 7.68 310.52 391.55
60% 6.63 6.63 9.21 9.21 370.9 467.94
70% 7.74 7.74 10.75 10.75 432.67 544.95
80% 8.84 8.84 12.28 12.28 492.63 620.44
90% 9.95 9.95 13.82 13.82 553.76 695.26
100% 11.06 11.06 15.36 15.36 612.32 769.57

With standard settings we were quite worried about the 12V rail since it was already generating lower than expected results even at lower loads. A few of the rails even came close to dropping out of spec. Again, we were able to regulate these rails quite successfully using the P-Tuner software to generate a better result under lower loads. At higher loads the software was less successful at regulating voltages, since we were already using pretty much everything the PSU could put out.





5Vsb and Standby Efficiency Dynamic Testing
Comments Locked

23 Comments

View All Comments

  • strikeback03 - Tuesday, July 24, 2007 - link

    Does the software need to be running for the voltage regulation to work? Or can you make changes then close the software and have the changes still work on the PSU?

    Also I'd guess if UV lighting is that useful for a case you could swap the blue LEDs for some UV ones - looks like enough wire is exposed to cut the blue ones and solder in UV ones.
  • Oberst - Tuesday, July 24, 2007 - link

    Hello,
    nice review (i wouldn't expect anything else of you). But I've got a question about the measuring-software: Was it reliable, when measuring voltages? You already mentioned, that the wattage was not reliable. So I'd like to know, if that was because of wrong measured amps or volts.
    greets Oberst.
  • Christoph Katzer - Tuesday, July 24, 2007 - link

    Voltages have been quite accurate; amps have been wrong in almost every case.
  • qpwoei - Tuesday, July 24, 2007 - link

    Once you've got the ripple measurements sorted out, it'd be nice to get some scope traces as the load changes. Poor transient response of the rails can cause all sorts of hard-to-diagnose problems in the real world.
  • Christoph Katzer - Tuesday, July 24, 2007 - link

    We use a scope to follow response on the rails but until now we feel the data is not good enough to present. If there would be something to extraordinary to tell we surely would.
  • bob4432 - Tuesday, July 24, 2007 - link

    what about that? a good quality unit, the Corsair 520HX seems to be a lot of people's favorite lately, how does it really stack up? or some of the FSP "Green" units - are they really that efficient? what about seasonic - really as good as everyone says?

    these reports are all fine and dandy, but you are catering to possibly 5% of your user base, yes even here 800W is extreme overkill.

    and it is not a $$$ issue but rather a reality issue. i am surprised you guys testing these are continuing the thought process by only reviewing the upper wattage units and thus making everyone think they need one when they don't - people on review 750W psus, so i must need one...come on guys
  • Christoph Katzer - Tuesday, July 24, 2007 - link

    Will come. No worries about that. At the moment we are just starting as you can see and of course every company wants to have the best PSU tested first. We'll have lower ones very soon but need to work on that mountain of PSUs here first. With 380w you will see a Seasonic pretty soon for example.
  • bob4432 - Tuesday, July 24, 2007 - link

    will definitely be looking forward to them :)
  • ATWindsor - Tuesday, July 24, 2007 - link

    I disagree that an OCP per rail i s a good thing, it onyl makes using the PSU more of a hassle, since you can draw a lot less from the PSU on 12V than the specs would make possible, if you are unlucky and draw most of it from one rail. Several manufacturers have one big rail without any know safety-problems, having an OCP for the combined drav from the 12V-lines however is a good thing.

    AtW
  • dare2savefreedom - Tuesday, July 24, 2007 - link

    I would be interested in knowing how a psu runs with dual 8800gtxs in virginia in summertime in an old house with a window air conditioner.

    Not these theoretical white glove clean room lab environment tests.

    triple sli 8800gtx?

    come one stop playing with your iphone.

Log in