Testing Methodology

Although the testing of a cooler appears to be a simple task, there are many factors that need to be considered. Proper thermal testing cannot be performed with a cooler mounted on a single chip, for multiple reasons. Some of these reasons include the instability of the thermal load and the inability to fully control and/or monitor it, as well as the inaccuracy of the chip-integrated sensors. It is also impossible to compare results taken on different chips, let alone entirely different systems, which is a great problem when testing computer coolers, as the hardware changes every several months. Finally, testing a cooler on a typical system prevents the tester from assessing the most vital characteristic of a cooler, its absolute thermal resistance.

The absolute thermal resistance defines the absolute performance of a heatsink by indicating the temperature rise per unit of power, in our case in degrees Celsius per Watt (°C/W). In layman's terms, if the thermal resistance of a heatsink is known, the user can assess the highest possible temperature rise of a chip over ambient by simply multiplying the maximum thermal design power (TDP) rating of the chip with it. However, extracting the absolute thermal resistance of a cooler is no simple task.

The thermal load has to be perfectly even, steady and controllable. The latter is critical as thermal resistance varies depending on the magnitude of the thermal load. Therefore, even if it would be possible to assess the thermal resistance of a cooler while it is mounted on a working chip, it would not suffice, as a large change in the thermal load can yield very different results.

Appropriate thermal testing requires the creation of a proper testing station and the use of laboratory-grade equipment. To accomplis this, we created a thermal testing platform with a fully controllable thermal energy source that may be used to test any kind of cooler, regardless of its design and/or compatibility. The thermal cartridge inside the core of our testing station can have its power adjusted between 60 W and 340 W, in 2 W increments (and it never throttles).

Furthermore, monitoring and logging of the testing process via software minimizes the possibility of human errors during testing. A multifunction data acquisition module (DAQ) is responsible for the automatic or manual control of the testing equipment, the acquisition of the ambient temperature, and the in-core temperatures via PT100 sensors. It also handles the logging of the test results and the mathematical extraction of performance figures.

Finally, as noise measurements are a bit tricky, their measurement is only performed manually. Fans can have significant variations in speed from their rated values, thus their actual speed during the thermal testing is acquired via a laser tachometer. The fans (and pumps, when applicable) are powered via an adjustable, fanless desktop DC power supply and noise measurements are taken 1 meter away from the cooler, in a straight line from the fan engine.

At this point we should also note that the Decibel scale is logarithmic, which means that roughly every 3 dB(A) the sound pressure doubles. Therefore, the difference of sound pressure between 30 dB(A) and 60 dB(A) is not "twice as much" but nearly a thousand times greater. The table below should help you cross-reference our test results with real-life situations.

<35dB(A) Virtually inaudible
35-38dB(A) Very quiet (whisper)
38-40dB(A) Quiet (slight humming)
40-44dB(A) Normal (humming noise, comfortable level)
44-47dB(A) Loud* (strong aerodynamic noise)
47-50dB(A) Very loud (strong whining noise)
50-54dB(A) Extremely loud (About equivalent to a typical hairdryer)
>54dB(A) Intolerable for home/office use, special applications only.

*noise levels above this are not suggested for daily use

The Reserator 3 Max Dual AIO CPU Cooler Testing Results, Maximum Fan Speed (12 Volts)
Comments Locked

52 Comments

View All Comments

  • mickulty - Wednesday, August 20, 2014 - link

    "Although we cannot fully explain why, it seems that the Reserator 3 Max Dual cannot dissipate high quantities of thermal energy quickly enough."

    Could it be something to do with the overlapping cooling path?
  • E.Fyll - Wednesday, August 20, 2014 - link

    Although I cannot really calculate it, I believe that the surface of the pipes is simply much smaller than the surface of a classic two-pass radiator. Therefore, even though it can dissipate heat very quickly via its sizable fin area, the surface between the array and the tubing is not sufficient to maintain a very large energy transfer.

    This simply is an assumption on my part and is not based on any form of evidence.