Benchmark Configuration

We used a point-to-point configuration to eliminate the need for a switch. We have one machine that we use as the other “end of the network” and one machine on which we measure throughput and CPU load. We used Ixia IxChariot to test the network performance.

Server One ("the other end of the network"):
Supermicro SC846TQ-R900B chassis
Dual Intel Xeon 5160 “Woodcrest” at 3GHz
Supermicro X7DBN Rev1.00 Motherboard
Intel 5000P (Blackford) Chipset
4x4GB DDR2-667 Kingston Value Ram CAS 5
BIOS version 03/20/08

Server two (for measurements):
Supermicro A+ 2021M-UR+B chassis
Dual AMD Opteron 8389 “Shanghai” at 2.9GHz
Supermicro H8DMU+ Motherboard
NVIDIA MCP55 Pro Chipset
8x2GB of Kingston DDR2-667 Value RAM CAS 5
BIOS version 080014 (12/23/2009)

NICs

Both servers were equipped with the following NICs:

  • Two dual-portIntel PRO/1000 PT Server adapter (82571EB) (four ports in total)
  • One Supermicro AOC-STG-I2 dual-port 10Gbit/s Intel 82598EB
  • One Neterion Xframe-E 10Gbit/s

We tested the NICs using CentOS 5.4 x64 Kernel 2.6.18 and VMware ESX 4 Update 1

Important note:the NICs used are not the latest and greatest. For example, Neterion already has a more powerful 10Gbit NIC out, the Xframe 3100. We tested with what had available in our labs.

Drivers CentOS 5.4
Neterion Xframe-E: 2.0.25.1
Supermicro AOC-STG-I2 dual-port: 2.0.8-k3, 2.6.18-164.el5

Drivers ESX 4 Update 1 b208167
Neterion Xframe-E: vmware-esx-drivers-net-s2io-400.2.2.15.19752-1.0.4.00000
Supermicro AOC-STG-I2 dual-port: vmware-esx-drivers-net-ixgbe-400.2.0.38.2.3-1.0.4.164009
Intel PRO/1000 PT Server adapter: vmware-esx-drivers-net-e1000e-400.0.4.1.7-2vmw.1.9.208167

Index The Hardware
Comments Locked

49 Comments

View All Comments

  • krazyderek - Monday, March 8, 2010 - link

    Furthermore where do the upgrades stop? Dual NIC's are common on workstations but you can also get triple and quad built in, or add in cards. Where do you stop?

    Maybe i'm looking for an answer to a question that doesn't have a clear cut answer, it's just a balancing act, and you have to balance performance with home much you have to spend.

    If you upgrade the server to remove it as a bottleneck, then your clients become the bottleneck, if you team up enough client NIC's then your server become's the bottleneck again, if you upgrade the server with PCIe solid state drive like the Fusion IO and several 10Gb connections then your clients and your switch start to become the bottleneck, and on and on....
  • Kjella - Tuesday, March 9, 2010 - link

    If you use "IT" "upgrades" and "end" in the same post, well... it doesn't end. It ends the day megacorporations can run off a handful of servers, which is never because the requirements keep going up. Like for example your HDD bottleneck, well then let's install a SSD array that can run tens (hundreds?) of thousands of IOPS and several Gbit/s speeds and something else becomes the bottleneck. It's been this way for decades.
  • has407 - Tuesday, March 9, 2010 - link

    You stop when you have enough performance to meet your needs. How much is that? Depends on your needs. Where's the bottleneck? A bit of investigation will identify them.

    If you have a server serving a bunch of clients, and the server network performance is unacceptable, then increasing the number of 1Gbe ports on the server is likely your best choice if you have expansion capability; if not then port/slot consolidation using 10Gbe may be appropriate. However, if server performance is limited by other factors (e.g., CPU/disk), then that's where you should focus.

    If you have clients hitting a server, and the client network performance is unacceptable (and the server performance is OK), then (in general) aggregating ports on the client won't get you much (if anything). In that case 10Gbe on the client may be appropriate. However, if client performance is limited by other factors (e.g., CPU/disk), then that's where you should focus.

    Link aggregation works best when traffic is going to different sources/destinations, and is generally most useful on a server which is serving multiple clients (or between switches with a variety of end-point IP's).

    4X 1Gbe links != 1x 4Gbe link. Link aggregation and load balancing across multiple links is typically based on source/destination IP. If they're the same, they'll follow the same link/path, and link aggregation won't buy you much because all of the packets from the same source/destination are following the same path--which means they go over the same link, which means that the speed is limited to that of the single fastest link. (Some implementations can also load balance based on source/destination port as well as IP, which may help in some situations.)

    That means that no matter how many 1Gbe links you have aggregated on client or server, the end-to-end speed for any given source/destination end-to-end IP pair (and possibly port) will never exceed that of a single 1Gbe link. (While there are ways to get around that, it's generally more trouble than it's worth and can seriously hurt performance.)
  • krazyderek - Tuesday, March 9, 2010 - link

    I thought this is why you had to use Link Aggregation and NIC teaming in combination, giving the client and server one IP each on multiple ethernet cords, so that when a client with 2xnic is doing say, sequential transfer from a server with 2x 3x or 4x then you could get 240MB/s throughput if the storage systems can handle it on either end, but when a 2x client connects to anther 1x client then you're limited by the slower of the two connections and thus only capable of 120MB/s max, which would open the door to still have 120MB/s combing from another client at the same time.

    Maybe it's all this SSD talk as of late, but i just want to see some of those options and bottlenecks tackled in real life and i just don't happen to have 5 or 10 SSD's kicking around to try it myself.
  • has407 - Wednesday, March 10, 2010 - link

    Link Aggregation (LACP) == NIC teaming (c.f., 802.3ad/802.1AX). Assigning different IP's will not get you anything unless higher layers are aware and are capable (e.g., use multipath which can improve performance, but in my experience not a lot--and it comes with overhead).

    Reordering Ethernet frames or IP packets can carry a heavy penalty--more than it's worth in many (most?) cases, which is why packets sent from any endpoint pair will (sans higher-order intervention) follow the same path. Endpoint pairs are typically based on IP, although some switches also use the port numbers (i.e., path == hash of IPs in the simple case, path == hash of IPs+ports in more sophisticated case). Which is why you genrally won't see performance exceed the fastest *single physical link* between endpoints (regardless of how many links you've teamed/aggregated), and which is why a single fast link can be better than teamed/aggregated links.

    E.g., team 4x 1Gbe links on both client and server. You generally won't see more than 1Gb from the client to the server for any given xfer or protocol, If you run multiple xfer's using differnt protocols (i.e., different ports) and you have a smart switch, you may see > 1Gb.

    In short, if you have a client with 4x 1Gb teamed/aggregated NICs, you won't see >1Gb for any IP/port pair, and probably not for any IP pair (depending on the switch/NIC smarts and how you've done your port aggregation/teaming) on the client, switch and server. Which again is why a single faster link is generally better than teaming/aggregation.

    There's a simple way for you to test it... fire up an xfer from a client with teamed NICs to a server with plenty of bandwidth. In most cases it will max out at the rate of the fastest single physical link on the client (or server). Fire up another xfer using the same protocol/port. In most cases the aggregate xfer will remain about the same (all packets are following the same path). If you see an increase, congratulations, your teaming is using both IP and port hashing to distribute traffic.
  • Lord 666 - Monday, March 8, 2010 - link

    In the market for a new SAN for a server in preparation for a consolidation/virtualization/headquarters move, one of my RFP requirements was for 10gbe capabilities now. Some peers of mine have questioned this requirement stating there is enough bandwidth with etherchanneled 4gb nics and FC would be the better option if thats not enough.

    Thank you for doing this write up as it confirms that my hypothesis is correct and 10gbe will/is a valid requirement for the new gear from a very forward looking view.

    It would be nice to see the same kit used in combination with SANS. With the constant churn of new gear, this will be very helpful.
  • has407 - Monday, March 8, 2010 - link

    Agree. Anyone who suggests FC is the answer today is either running on inertia or trying to justify a legacy FC investment/infrastructure.

    Build on 10Gbe if at all possible; if you need FC in places, look at FCoE.
  • mino - Tuesday, March 9, 2010 - link

    FC is good solution where iSCSI over Gbit is not enough but 10Gbps, along with all the teething troubles, is just not worth it.
    FC is reliable, 4Gb is no overpriced and has none of the issues of iSCSI.
    It just works.

    Granted, for heavily loaded situations, especially on blades, 10G is the way to go.
    But for many medium loads, FC is often the simpler/cheaper option.
  • JohanAnandtech - Tuesday, March 9, 2010 - link

    Which issues of iSCSI exactly? And FC is still $600 per port if I am not mistaken?

    Not to mention that you need to import a whole new kind of knowledge in your organisation, while iSCSI works with the UTP/Ethernet tech that every decent ITer knows.
  • mino - Tuesday, March 16, 2010 - link

    The issues with latency, reliability, multipathing etc. etc.

    Basically the strongest point of iSCSI is the low up-front price and single-infrastructure mantra.
    Optimal for small or scale-out. Not so much for mid projects.

    "... while iSCSI works with the UTP/Ethernet tech that every decent ITer knows ..."
    Sorry to break the news, but any serious IT shop has an in-house FC-storage experience going back a decade or more.

    1Gbps is really not in a competition with FC. It is an order of magnuitude below in latency and protocol overhead (read low IOps).

    Whe the fun starts is 10G vs FC and serious 10G infrastructure is actually more expensive per port than FC.

    When iSCSI over 10G shines is in port consolidation oportunity.
    Not in bandwith, not in latency, not in price/port.