Game Loading Performance

For our game loading tests, we used two games: Far Cry and Unreal Tournament 2004. Both games were installed, in full, to the hard drive. We then used no-CD patches to prevent any accessing of the CD/DVD drive to skew the loading process. Both games were installed to a clean drive without anything else present on the drive (the OS is located on a separate drive).

Our Far Cry test consists of starting a campaign with the default difficulty level, hitting escape to skip the introductory movie and beginning the stop watch timer at first sight of the loading screen. The stop watch timer is stopped as soon as the loading screen disappears. The test is repeated three times with the final score reported being an average of the three. In order to avoid the effects of caching, we reboot between runs. All times are reported in seconds; lower scores, obviously, being better.

Far Cry Level Loading Performance

We were hoping to see some sort of performance increase in the game loading tests, but the RAID array didn't give us that. While the scores put the RAID-0 array slightly slower than the single drive Raptor II, you should also remember that these scores are timed by hand and thus, we're dealing within normal variations in the "benchmark".

Our Unreal Tournament 2004 test uses the full version of the game and leaves all settings on defaults. After launching the game, we select Instant Action from the menu, choose Assault mode and select the Robot Factory level. The stop watch timer is started right after the Play button is clicked, and stopped when the loading screen disappears. The test is repeated three times with the final score reported being an average of the three. In order to avoid the effects of caching, we reboot between runs. All times are reported in seconds; lower scores, obviously, being better.

Unreal Tournament 2004 Level Loading Performance

In Unreal Tournament, we're left with exactly no performance improvement, thanks to RAID-0.

SYSMark Performance Summary Final Words
Comments Locked

127 Comments

View All Comments

  • timw - Thursday, July 8, 2004 - link

    This isn't really anything new. As someone else mentioned, seek time and cache size with the right firmware optimizations are the most important. RAID 0 won't be able to improve that, and may actually be slower than a single drive in many instances. If you don't believe what Anandtech has to say, take a look at the latest article at storagereview.com.
  • Pumpkinierre - Thursday, July 8, 2004 - link

    Wrong again, mdrohn, Australia to be exact, but I was using an Oxford dictionary. The hyperdictionary.com (USA based I think as it advertises cheap dental insurance for US residents) gives redundancy as:

    Definition: [n] repetition of an act needlessly
    [n] the attribute of being superfluous and unneeded; "the use of industrial robots created redundancy among workers"
    [n] (electronics) a system design that duplicates components to provide alternatives in case one component fails
    [n] repetition of messages to reduce the probability of errors in transmission

    Which agrees with both our definitions. Yours is more correct electronically. Hyperdictionary has a more extensive electronic description but doesnt add much more to the above electronic definition:
    http://www.hyperdictionary.com/dictionary/redundan...

    I'm at odds with that electronic meaning of redundancy. After all the language came before the electronics.
  • mdrohn - Thursday, July 8, 2004 - link

    Heh, I guess that means you are writing from Britain, Pumpkinierre. That special meaning of 'redundancy' in the workplace context of someone losing their job is unknown here in the USA. In fact I'd never heard it in my life until watching 'The Office' on DVD last month ;) We call that layoffs or downsizing here.

    The electronics/systems meaning I posted was also taken straight from a dictionary.
  • Pumpkinierre - Thursday, July 8, 2004 - link

    Your job becomes redundant when you are no longer of use. You then get a redundancy payout based on the years worked etc.. So I think they initially used the term to describe drives that were no longer of use as they had been replaced by newer bigger drives. My dictionary has redundant as meaning superfluous which is more like your definition, #100, and I suppose you could regard a backup drive as such....until your main drive lets go. So, I dont like the usage of redundancy for duplexed or mirrored drives.
  • mdrohn - Wednesday, July 7, 2004 - link

    "Redundancy means of no further use."

    Actually, 'redundant' more precisely means 'exceeding what is required' or 'exactly duplicating the function or meaning of another', which is an important distinction.

    'Redundancy' in an electronics or systems context means 'incorporating extra components that perform the same function in order to cope with failures and errors'. Thus RAID 0 is not, strictly speaking, a 'redundant' array of disks despite its RAID name, since every drive in RAID 0 records different data. RAID 1 is classic redundancy--all the drives in a RAID 1 array are reading and writing exactly the same data.
  • Pumpkinierre - Wednesday, July 7, 2004 - link

    I dont know about that latency increase with RAID. Seek times dont seem to be much affected in reviews I've seen. If the controller reads the drives simultaneously then there shouldnt be much effect on latency.

    (will it make it to the 6th page?!)
  • masher - Wednesday, July 7, 2004 - link

    > I'm fairly certain that the performance
    > advantages of having 4 or 5 striped drives are
    > likely to be a lot better than just 2...

    No, not for ATA drives. You're still limited to the max bandwidth of 133MB/s (150 for some SATA implementations), so beyond 3 drives you don't get the full transfer rate of each drive. Plus, the latency gets worse the more drives you add...with 5 or more drives, your mean latency is essentially your max latency of any single drive.

    So a larger array is a repeat of the 2-drive situation. Its much faster in the rare case of a disk-bound app transferring huge files...and no faster (or possibly slightly slower) the rest of the time.

    You are right on one thing though. Cheaper (translation: slower) disks would tend to look a bit better here. Not a huge difference, but the slower the disk, the more likely the app is to be disk-bound.
  • kapowaz - Wednesday, July 7, 2004 - link

    Perhaps the review ought to have pointed out what RAID stands for: Redundant Array of *Inexpensive* Disks. The idea is to improve the performance or reliability of a system by using many smaller/cheaper disks compared to using a single expensive disk. Often this isn't the case (I doubt anyone would say the 15krpm disks in modern servers are 'inexpensive'), but the origin behind the technology remains applicable today.

    Maybe a better test would be to take some cheap disks and see how well they perform. Also, am I not right in thinking that SATA RAID allows for more than just two devices? I'm fairly certain that the performance advantages of having 4 or 5 striped drives are likely to be a lot better than just 2...
  • masher - Wednesday, July 7, 2004 - link

    Umm, MadAd...The "array" of drives can't fail unless a drive in it fails...and it will always fail if one of its drives does. Its just a logical grouping, not a separate entity.

    Furthermore, MTBF is the wrong statistic to use here. MTTF is the relevant one.

    Obviously the raid controller itself could fail, but this is outside the scope of the argument. And such a failure is highly unlikely to impact data in any case.
  • MadAd - Tuesday, July 6, 2004 - link

    "But when we are talking about an ARRAY of drives, the operating life of each individual drive in the array is not what is at issue. What is relevant is ARRAY failure, not DRIVE failure."

    Are you also trying to say that if the array fails without a drive failing then thats still down to the drives MTBF? wouldnt that be an array MTBF?

    If a drive fails in Raid0 then of course we expect the array will fail. If a drive does not fail but the array fails (and you can reuse the drive) then thats nothing to do with the drives MTBF is it? The drives not failed, its still got service life, the array failed. You'll need a different way to measure the chance of an array failure since (unless its connected with a drive failure) its nothing to do with the expected longevity of the components that we measure by drive manufacturers MTBF figures of service life.

Log in