Testing Methodology

Although the testing of a cooler appears to be a simple task, there are many factors that need to be considered. Proper thermal testing cannot be performed with a cooler mounted on a single chip, for multiple reasons. Some of these reasons include the instability of the thermal load and the inability to fully control and/or monitor it, as well as the inaccuracy of the chip-integrated sensors. It is also impossible to compare results taken on different chips, let alone entirely different systems, which is a great problem when testing computer coolers, as the hardware changes every several months. Finally, testing a cooler on a typical system prevents the tester from assessing the most vital characteristic of a cooler, its absolute thermal resistance.

The absolute thermal resistance defines the absolute performance of a heatsink by indicating the temperature rise per unit of power, in our case in degrees Celsius per Watt (°C/W). In layman's terms, if the thermal resistance of a heatsink is known, the user can assess the highest possible temperature rise of a chip over ambient by simply multiplying the maximum thermal design power (TDP) rating of the chip with it. However, extracting the absolute thermal resistance of a cooler is no simple task.

The thermal load has to be perfectly even, steady and controllable. The latter is critical as thermal resistance varies depending on the magnitude of the thermal load. Therefore, even if it would be possible to assess the thermal resistance of a cooler while it is mounted on a working chip, it would not suffice, as a large change in the thermal load can yield very different results.

Appropriate thermal testing requires the creation of a proper testing station and the use of laboratory-grade equipment. To accomplis this, we created a thermal testing platform with a fully controllable thermal energy source that may be used to test any kind of cooler, regardless of its design and/or compatibility. The thermal cartridge inside the core of our testing station can have its power adjusted between 60 W and 340 W, in 2 W increments (and it never throttles).

Furthermore, monitoring and logging of the testing process via software minimizes the possibility of human errors during testing. A multifunction data acquisition module (DAQ) is responsible for the automatic or manual control of the testing equipment, the acquisition of the ambient temperature, and the in-core temperatures via PT100 sensors. It also handles the logging of the test results and the mathematical extraction of performance figures.

Finally, as noise measurements are a bit tricky, their measurement is only performed manually. Fans can have significant variations in speed from their rated values, thus their actual speed during the thermal testing is acquired via a laser tachometer. The fans (and pumps, when applicable) are powered via an adjustable, fanless desktop DC power supply and noise measurements are taken 1 meter away from the cooler, in a straight line from the fan engine.

At this point we should also note that the Decibel scale is logarithmic, which means that roughly every 3 dB(A) the sound pressure doubles. Therefore, the difference of sound pressure between 30 dB(A) and 60 dB(A) is not "twice as much" but nearly a thousand times greater. The table below should help you cross-reference our test results with real-life situations.

<35dB(A) Virtually inaudible
35-38dB(A) Very quiet (whisper)
38-40dB(A) Quiet (slight humming)
40-44dB(A) Normal (humming noise, comfortable level)
44-47dB(A) Loud* (strong aerodynamic noise)
47-50dB(A) Very loud (strong whining noise)
50-54dB(A) Extremely loud (About equivalent to a typical hairdryer)
>54dB(A) Intolerable for home/office use, special applications only.

*noise levels above this are not suggested for daily use

The Reserator 3 Max Dual AIO CPU Cooler Testing Results, Maximum Fan Speed (12 Volts)
Comments Locked

52 Comments

View All Comments

  • C'DaleRider - Tuesday, August 19, 2014 - link

    Looks like it's suffered the fate most radiators that used round tubes had....poor performance, and probably due to laminar flow issues. Read on another forum about testing done by some of the "pioneers" in watercooling and issues faced by round tube radiators. Lack of surface area being actively cooled and laminar flow problems.

    Ever wonder why the "real" water cooling crowd has almost no round tube radiators to choose from?
  • liu_d - Tuesday, August 19, 2014 - link

    The reason most rads don't use round tubing is cost. If you look at the few radiators on the market that do (Aquacomputer Airplex, Feser Admiral), they are considerably more expensive than corrugated-fin radiators of similar size. This is because instead of just folding the fins back and forth between flat water tubes, round tubes need a soldered fin stack (like most heatpipe air coolers) which is more complicated to manufacture.
  • owan - Wednesday, August 20, 2014 - link

    Well, you're right that those radiators are expensive, likely due to the construction complexity, but they really don't perform anywhere close to accordingly for their cost. I've seen results showing that the Aquacomputer rads perform measurably worse than typical rads at half the price, likely for the reasons C'DaleRider mentioned.
  • garadante - Tuesday, August 19, 2014 - link

    I would really like to see a roundup of the radiators when they're all using the same fan. I was really impressed by the Cooler Master Nepton 280L... Until I noticed fan speed and noise levels. The H110 seems like the best CLC in this roundup by far for having #2/#3 performance at significantly lower fan speeds and noise levels. I know there's the argument for testing CLCs exactly as they come in the packaging, but if you're spending $100+ on a radiator already for a 5-10 C temperature decrease, another $20-30 for a further 5 degree C decrease or even greater isn't a stretch. And if you do such a roundup, having a standard push vs push-pull setup would be great too, to see what the benefits are and which radiators benefit most from the increase static pressure.
  • garadante - Tuesday, August 19, 2014 - link

    And it would be worth looking into if the Corsair H105/similar thick radiators perform better with certain fan setups. Because as it is, the performance is severely lacking in all of the reviews I've seen for the H105 and other thick radiators compared to a 280mm radiator. It would be interesting to find out if the extra radiator thickness comes in handy with enough static pressure or airflow or some combination thereof, or if it's just better to go for more surface area in all use cases. It's much easier to find a case compatible with a 280mm radiator than an extra thick radiator, especially if you want to use push-pull fans.
  • HanzNFranzen - Thursday, August 21, 2014 - link

    I see where you are coming from, but the problem with testing all rads with the same fan is that each radiator performs differently depending on the type of fan used. You could have radiator X that performs better than radiator Y with a Noctua fan and then see the results change in favor of radiator Y when using Corsair fans (just using brands as an example). Combinations of different fan pressures and different radiator thickness and fin densities are all going to skew the results from one fan to another.
  • skrewler2 - Saturday, August 23, 2014 - link

    you are correct, but that's the entire point. also, no one said anything about using only 1 fan. would be nice to see the results with it stock and some of the most popular / performant fans. Then run the tests with the same fans against all the other units.
  • kwrzesien - Wednesday, August 20, 2014 - link

    I'm not sure why he lowered the pump voltage to 7V along with the fans (which seems to be how the article describes it), as far as I can tell most systems leave the pump at a full 12V without any noise issues. Who knows what impact this has on the performance of each of these CLC's but I think it has 0% chance of being used this way in the real world.
  • E.Fyll - Wednesday, August 20, 2014 - link

    The pump voltage is controlled by your motherboard and will be reduced if the thermal control is not disabled in the BIOS, much like it would do with a typical fan. Therefore, I am taking the path that the majority of users would take, which is to leave the BIOS at default settings and allow the thermal control to do its thing.

    Besides, "most" is not "all". For example, the Coolermaster V series is using a pump that is rather noisy. It would not be fair to test some coolers with the pump at maximum speed and some with the pump at a reduced speed, as this obviously has a sizable impact on performance. Everything is being tested under the exact same conditions, otherwise the very use of the word "testing" would be an insult to my ears.
  • E.Fyll - Wednesday, August 20, 2014 - link

    Actually, that would be misleading. The performance of the coolers would then rely on the P/V curve of the specific fan used for the test. Each radiator is causing a specific, unique pressure drop and each fan will behave different at each static pressure level. Therefore, the use of a specific fan would favor some designs and cripple others. Switching that fan to another model would yield different results as well. I cannot possibly test every fan out there. I can only be testing each product as a stand-alone solution, it is not possible to account for every possible modification that users may or may not perform.

Log in